TA6000

Integrated system

TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER
Included
ENCLOSURE
Not specified
NOMINAL ENERGY
10.24–20.48 kWh
AC CONFIGURATION
120 V US / 230 V EU AC options
Start your project ↗

Specifications

Model / configurationEnergy (kWh)AC options (kW)
TA6000-M210.246–10
TA6000-M315.366–12
TA6000-M420.486–12

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

ModelDimensions (mm)Approx. kg
TA6000-M2590 × 570 × 1880 / W × D × H244
TA6000-M3590 × 570 × 1880 / W × D × H286
TA6000-M4590 × 570 × 1880 / W × D × H328

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

Backup storage for your home and its seasons.

Keep connectivity, refrigeration and selected home-office loads in the plan. Choose an integrated cabinet, compact battery or modular stack around the space you have, then match the design to coastal moisture or inland winter temperatures.

Temperature:
Operating −20 to 60 °C
ENCLOSURE
Not specified
01

Cold inland garage or service room

An accessible, dry service room gives an inland home a dedicated place for backup storage. Some interior-plateau locations experience freezing winter nights, so the room temperature belongs in the charging plan.

Choose an integrated cabinet for a new system or battery-only storage for a compatible inverter. Several families list charging from 0 °C; an explicitly supported heating configuration can be discussed for the exact TR model, without assuming below-zero charging.

Can the installation room fall below 0 °C?
  • What charging-temperature protection or confirmed heating configuration will the selected battery use?
02

Protected storage for a coastal home

Use a dedicated sheltered service space to keep the battery and connections organised. The Western Cape receives most rain in winter, while other regions have different seasonal patterns.

TR Pro provides a compact battery format, while HP Ultra offers modular capacity choices; both list IP66 enclosures. Pair the selected housing with an appropriate dry location and review actual rain, condensation and coastal exposure.

Can rain, spray, condensation or standing water reach the equipment?
  • Is the proposed room coastal, and has corrosion exposure been reviewed for the actual model?
03

Warm enclosed utility area

A dedicated utility area keeps backup equipment separate from everyday living space and leaves access for servicing. Match the format to the room and the loads you want to support.

EU 230 V combines the battery and inverter in one IP21 cabinet. Battery-only options let you work with a compatible external inverter. Preserve cooling and service space; request the exact HP Ultra configuration temperature limits when comparing modular storage.

What is the highest expected room temperature during use?
  • Is the inverter/battery combination confirmed, and can cooling and service access remain unobstructed?
Specifications
  • Separate charging and discharging limits. TR Pro and HP K list charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. These are not automatic below-zero charging permissions or full-power derating curves.
  • Specify the enclosure for the actual room. TR Pro and HP Ultra list IP66; EU lists IP21; TB rack lists IP20; TR standard and HP K list IP20 with IP54 optional. Coastal, wet or dusty exposure still requires model-specific review.
  • Size backup around the duration and essential circuits you choose, without assuming an outage schedule. Winter space heating and electric water heating can dominate energy demand and need their own running-power, duration and inverter-capacity review.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

Original terminal labels
Original terminal labelsConnection panel labelled for load, grid, optional generator, PV and communication.
Terminal panel close-up
Terminal panel close-upClose-up of the cabinet terminal panel.
Original breaker labels
Original breaker labelsBattery, PV1, PV2, load and grid breakers in the illustrated compartment.
Breaker compartment close-up
Breaker compartment close-upCircuit breakers within the cabinet's breaker compartment.
Upper cabinet and service bay
Upper cabinet and service bayUpper cabinet compartment with the inverter and connection area.
Cell assembly detail
Cell assembly detailBattery cell tops in a partial internal illustration.

Know your interfaces.

Power connections

Load Output
Output position identified as Load Output in the brochure.
Grid Input
Connection position identified as Grid Input.
Generator Input (optional)
The generator input is explicitly marked optional in the original callout.
PV Input
PV connection area identified by the original callout.
PV1 Input Breaker
Breaker identified for PV1 Input.
PV2 Input Breaker
Breaker identified for PV2 Input.

Communication

Communication Port
Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

Controls & indicators

Battery Breaker
Breaker labelled for the battery section.
Load Breaker
Breaker identified for the load connection.
Grid Breaker
Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16