HP Ultra

High-voltage battery

HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP66 / aluminium alloy
NOMINAL ENERGY
8–48 kWh
BATTERY VOLTAGE
Confirm selected configuration
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Max. DC (kW)
HP Ultra-8.084
HP Ultra-16.0168
HP Ultra-24.02412
HP Ultra-32.03216
HP Ultra-40.04020
HP Ultra-48.04824

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

ModelDimensions (mm)Approx. kg
HP Ultra-8.0950 × 315 × 575 / W × D × H75
HP Ultra-16.0950 × 315 × 880 / W × D × H130
HP Ultra-24.0950 × 315 × 1185 / W × D × H185
HP Ultra-32.0950 × 315 × 1490 / W × D × H240
HP Ultra-40.0950 × 315 × 1795 / W × D × H295
HP Ultra-48.0950 × 315 × 2100 / W × D × H350

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

Backup storage for your home and its seasons.

Keep connectivity, refrigeration and selected home-office loads in the plan. Choose an integrated cabinet, compact battery or modular stack around the space you have, then match the design to coastal moisture or inland winter temperatures.

Temperature:
Confirm selected configuration
ENCLOSURE
IP66 / aluminium alloy
01

Cold inland garage or service room

An accessible, dry service room gives an inland home a dedicated place for backup storage. Some interior-plateau locations experience freezing winter nights, so the room temperature belongs in the charging plan.

Choose an integrated cabinet for a new system or battery-only storage for a compatible inverter. Several families list charging from 0 °C; an explicitly supported heating configuration can be discussed for the exact TR model, without assuming below-zero charging.

Can the installation room fall below 0 °C?
  • What charging-temperature protection or confirmed heating configuration will the selected battery use?
02

Protected storage for a coastal home

Use a dedicated sheltered service space to keep the battery and connections organised. The Western Cape receives most rain in winter, while other regions have different seasonal patterns.

TR Pro provides a compact battery format, while HP Ultra offers modular capacity choices; both list IP66 enclosures. Pair the selected housing with an appropriate dry location and review actual rain, condensation and coastal exposure.

Can rain, spray, condensation or standing water reach the equipment?
  • Is the proposed room coastal, and has corrosion exposure been reviewed for the actual model?
03

Warm enclosed utility area

A dedicated utility area keeps backup equipment separate from everyday living space and leaves access for servicing. Match the format to the room and the loads you want to support.

EU 230 V combines the battery and inverter in one IP21 cabinet. Battery-only options let you work with a compatible external inverter. Preserve cooling and service space; request the exact HP Ultra configuration temperature limits when comparing modular storage.

What is the highest expected room temperature during use?
  • Is the inverter/battery combination confirmed, and can cooling and service access remain unobstructed?
Specifications
  • Separate charging and discharging limits. TR Pro and HP K list charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. These are not automatic below-zero charging permissions or full-power derating curves.
  • Specify the enclosure for the actual room. TR Pro and HP Ultra list IP66; EU lists IP21; TB rack lists IP20; TR standard and HP K list IP20 with IP54 optional. Coastal, wet or dusty exposure still requires model-specific review.
  • Size backup around the duration and essential circuits you choose, without assuming an outage schedule. Winter space heating and electric water heating can dominate energy demand and need their own running-power, duration and inverter-capacity review.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

DC electrical / heatsink face - original callouts
DC electrical / heatsink face - original calloutsDC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.
Communication and parallel-interface face - original callouts
Communication and parallel-interface face - original calloutsCommunication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.
Communication-side detail (partial oblique view)
Communication-side detail (partial oblique view)Oblique detail of the stack's communication-side connector area.
Module top / mating surfaces
Module top / mating surfacesBattery module top and mating surfaces.

Know your interfaces.

Power connections

Positive Pole
Positive terminal identified by the original leader line on the electrical face.
Negative Pole
Negative terminal identified by the original leader line on the electrical face.

Communication

Bluetooth/WIFI Antenna
Antenna label on the upper communication-side area.
Backup Com
The brochure labels this connection 'Backup Com' but does not explain its exact role.
INV CAN/RS485 Com
The INV-labelled CAN/RS485 communication connection shown in the original diagram.
Parallel COM1
First parallel-communication label near the lower part of the illustrated interface face.
Parallel COM2
Second parallel-communication label near the lower part of the illustrated interface face.

Controls & indicators

Switch
Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.
DC Breaker
DC breaker on the electrical / heatsink face.
Breathing Light
Light strip called out at the upper front portion in the oblique construction view.

Structure & mounting

Heat Dissipation Aluminum Plate
Heat-dissipation aluminum plate called out on the slim electrical-side illustration.
Wall Mounted Bracket
Mounting brackets shown on the vent-side illustration.
PDU
PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.
Module
Repeated battery sections below the top PDU.
Base
Base at the bottom of the illustrated stack.
BMS Debugging Interface
BMS debugging interface identified on the communication-side illustration.
Pressure Relief Valve
Pressure-relief component called out in the communication-side oblique view.
GND
Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10