EU 230 V

Integrated system

EU 230 V.

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

INVERTER
Included
ENCLOSURE
IP21
NOMINAL ENERGY
10.24 / 16.076 kWh
AC CONFIGURATION
230 V AC / 50 or 60 Hz
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated AC (kW)
6.2K-10/16KWH-EU10.246.2
6.2K-10/16KWH-EU16.0766.2
12K-16KWH-EU16.07612

6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation.

ModelDimensions (mm)Approx. kg
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H105
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H130
12K-16KWH-EU552 × 254 × 1210 / L × W × H130

Communication: USB / RS485 / dry contact
Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C

Backup storage for your home and its seasons.

Keep connectivity, refrigeration and selected home-office loads in the plan. Choose an integrated cabinet, compact battery or modular stack around the space you have, then match the design to coastal moisture or inland winter temperatures.

Temperature:
Charge 0 to 55 °C; discharge −20 to 55 °C
ENCLOSURE
IP21
01

Cold inland garage or service room

An accessible, dry service room gives an inland home a dedicated place for backup storage. Some interior-plateau locations experience freezing winter nights, so the room temperature belongs in the charging plan.

Choose an integrated cabinet for a new system or battery-only storage for a compatible inverter. Several families list charging from 0 °C; an explicitly supported heating configuration can be discussed for the exact TR model, without assuming below-zero charging.

Can the installation room fall below 0 °C?
  • What charging-temperature protection or confirmed heating configuration will the selected battery use?
02

Protected storage for a coastal home

Use a dedicated sheltered service space to keep the battery and connections organised. The Western Cape receives most rain in winter, while other regions have different seasonal patterns.

TR Pro provides a compact battery format, while HP Ultra offers modular capacity choices; both list IP66 enclosures. Pair the selected housing with an appropriate dry location and review actual rain, condensation and coastal exposure.

Can rain, spray, condensation or standing water reach the equipment?
  • Is the proposed room coastal, and has corrosion exposure been reviewed for the actual model?
03

Warm enclosed utility area

A dedicated utility area keeps backup equipment separate from everyday living space and leaves access for servicing. Match the format to the room and the loads you want to support.

EU 230 V combines the battery and inverter in one IP21 cabinet. Battery-only options let you work with a compatible external inverter. Preserve cooling and service space; request the exact HP Ultra configuration temperature limits when comparing modular storage.

What is the highest expected room temperature during use?
  • Is the inverter/battery combination confirmed, and can cooling and service access remain unobstructed?
Specifications
  • Separate charging and discharging limits. TR Pro and HP K list charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. These are not automatic below-zero charging permissions or full-power derating curves.
  • Specify the enclosure for the actual room. TR Pro and HP Ultra list IP66; EU lists IP21; TB rack lists IP20; TR standard and HP K list IP20 with IP54 optional. Coastal, wet or dusty exposure still requires model-specific review.
  • Size backup around the duration and essential circuits you choose, without assuming an outage schedule. Winter space heating and electric water heating can dominate energy demand and need their own running-power, duration and inverter-capacity review.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail.

Original numbered interface map
Original numbered interface mapNumbered map of the AC, battery, PV and communication connections.
AC and battery connection side
AC and battery connection sideAC and battery connection side with cooling fans and the battery breaker.
AC and battery upper detail
AC and battery upper detailUpper AC connection area, cooling fans and BAT terminals.
PV and communication side
PV and communication sidePV and communication side, including the battery communication ports.
PV and communication upper detail
PV and communication upper detailVentilation grille above the PV and communication connection area.

Know your interfaces.

Power connections

AC input / output
The AC connection identified by number 1 in the original map.
AC input breaker
Breaker labelled for the AC input.
BAT+ / BAT-
Positive and negative battery terminals, as labelled in the source.
PV input
Input identified for the PV connection.

Communication

Parallel communication port
Communication connection labelled for parallel operation; configuration availability must be confirmed separately.
Dry contact control
Control interface labelled as dry contact in the brochure.
RS485 / BMS communication port
The communication connection named RS485/BMS in the original label.
Wi-Fi port
Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation.
USB communication port
Communication interface labelled USB.
Battery communication ports
The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs.

Controls & indicators

Battery breaker
Breaker identified for the battery section.

Source: EU 230 V product sheet · PDF page 1