# TR standard.

![TR standard](https://za.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp)

Low-voltage battery

# TR standard.

Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20; IP54 optional

NOMINAL ENERGY  5.12–20.07 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://za.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Nominal DC (V) |
| --- | --- | --- |
| TR4000WX | 5.12 | 51.2 |
| TR6000WX | 10.24 | 51.2 |
| TR8000WX | 14.336 | 51.2 |
| TR8500WX | 16.076 | 51.2 |
| TR10000WX | 20.07 | 51.2 |

Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 |
| TR6000WX | 600 × 750 × 160 / W × H × D | 95 |
| TR8000WX | 480 × 822 × 245 / W × H × D | 110 |
| TR8500WX | 480 × 822 × 245 / W × H × D | 115 |
| TR10000WX | 500 × 922 × 265 / W × H × D | 145 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C

## Backup storage for your home and its seasons.

Keep connectivity, refrigeration and selected home-office loads in the plan. Choose an integrated cabinet, compact battery or modular stack around the space you have, then match the design to coastal moisture or inland winter temperatures.

Temperature:  Charge 0 to 55 °C

ENCLOSURE  IP20; IP54 optional

01

### Cold inland garage or service room

An accessible, dry service room gives an inland home a dedicated place for backup storage. Some interior-plateau locations experience freezing winter nights, so the room temperature belongs in the charging plan.

Choose an integrated cabinet for a new system or battery-only storage for a compatible inverter. Several families list charging from 0 °C; an explicitly supported heating configuration can be discussed for the exact TR model, without assuming below-zero charging.

Can the installation room fall below 0 °C?

- What charging-temperature protection or confirmed heating configuration will the selected battery use?

02

### Protected storage for a coastal home

Use a dedicated sheltered service space to keep the battery and connections organised. The Western Cape receives most rain in winter, while other regions have different seasonal patterns.

TR Pro provides a compact battery format, while HP Ultra offers modular capacity choices; both list IP66 enclosures. Pair the selected housing with an appropriate dry location and review actual rain, condensation and coastal exposure.

Can rain, spray, condensation or standing water reach the equipment?

- Is the proposed room coastal, and has corrosion exposure been reviewed for the actual model?

03

### Warm enclosed utility area

A dedicated utility area keeps backup equipment separate from everyday living space and leaves access for servicing. Match the format to the room and the loads you want to support.

EU 230 V combines the battery and inverter in one IP21 cabinet. Battery-only options let you work with a compatible external inverter. Preserve cooling and service space; request the exact HP Ultra configuration temperature limits when comparing modular storage.

What is the highest expected room temperature during use?

- Is the inverter/battery combination confirmed, and can cooling and service access remain unobstructed?

Specifications

- Separate charging and discharging limits. TR Pro and HP K list charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. These are not automatic below-zero charging permissions or full-power derating curves.

- Specify the enclosure for the actual room. TR Pro and HP Ultra list IP66; EU lists IP21; TB rack lists IP20; TR standard and HP K list IP20 with IP54 optional. Coastal, wet or dusty exposure still requires model-specific review.

- Size backup around the duration and essential circuits you choose, without assuming an outage schedule. Winter space heating and electric water heating can dominate energy demand and need their own running-power, duration and inverter-capacity review.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized.

[![Front controls and side terminals](https://za.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://za.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)

Front controls and side terminals  Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet.

[![Rear bracket and terminal-side labels](https://za.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://za.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)

Rear bracket and terminal-side labels  Rear mounting bracket and side terminal area of the illustrated battery.

[![Circuit control switch detail](https://za.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://za.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)

Circuit control switch detail  Circuit control switch with ON/OFF markings.

[![Original rear three-quarter view](https://za.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://za.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)

Original rear three-quarter view  Rear three-quarter view showing the mounting bracket and terminal side.

[![Original side profile](https://za.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://za.elvorka.com/assets/product-details/tr-standard-side-profile.png)

Original side profile  Side profile showing communication ports and the recessed handle.

### Know your interfaces.

#### Power connections

Negative battery terminal  Negative DC battery power terminal as identified by the original arrow.

Positive battery terminal  Positive DC battery power terminal as identified by the original arrow.

#### Communication

Wi-Fi / Bluetooth  Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here.

Dry contact  Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied.

RS232 / CAN / RS485  Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation.

COM0 / COM1  Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits.

#### Controls & indicators

Touch screen  Touch-screen display identified in the original callout.

Running status indicator  Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified.

Alarm indicator  Alarm indication identified in the source.

SOC indicator  SOC indicator identified in the source; display thresholds are not specified.

Reset control  Reset control identified by the source; operating procedure is not given on this page.

Battery switch  Battery switch identified in the source; no switching rating is given in this callout.

#### Structure & mounting

Folding handle  Mechanical folding handle; not an electrical connector.

Wall-mounted bracket  Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here.

Rollers  Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface.

Source: Residential ESS brochure · PDF page 3 · printed pages 5-6

---

https://za.elvorka.com/en/products/tr-standard/