# TB rack.

![TB rack](https://za.elvorka.com/assets/optimized/2b8fe35077745c40-1584-q92.webp)

Low-voltage battery

# TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20

NOMINAL ENERGY  5.12–16.076 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://za.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Rated DC (kW) |
| --- | --- | --- |
| TB4000X | 5.12 | 5 |
| TB6000X | 10.24 | 10 |
| TB8000X | 14.336 | 10 |
| TB8500X | 16.076 | 10 |

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TB4000X | 482 × 178 × 420 / W × H × D | 42 |
| TB6000X | 482 × 223 × 550 / W × H × D | 78 |
| TB8000X | 482 × 223 × 710 / W × H × D | 109.5 |
| TB8500X | 482 × 223 × 710 / W × H × D | 112 |

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

## Backup storage for your home and its seasons.

Keep connectivity, refrigeration and selected home-office loads in the plan. Choose an integrated cabinet, compact battery or modular stack around the space you have, then match the design to coastal moisture or inland winter temperatures.

Temperature:  Charge 0 to 55 °C; discharge −20 to 60 °C

ENCLOSURE  IP20

01

### Cold inland garage or service room

An accessible, dry service room gives an inland home a dedicated place for backup storage. Some interior-plateau locations experience freezing winter nights, so the room temperature belongs in the charging plan.

Choose an integrated cabinet for a new system or battery-only storage for a compatible inverter. Several families list charging from 0 °C; an explicitly supported heating configuration can be discussed for the exact TR model, without assuming below-zero charging.

Can the installation room fall below 0 °C?

- What charging-temperature protection or confirmed heating configuration will the selected battery use?

02

### Protected storage for a coastal home

Use a dedicated sheltered service space to keep the battery and connections organised. The Western Cape receives most rain in winter, while other regions have different seasonal patterns.

TR Pro provides a compact battery format, while HP Ultra offers modular capacity choices; both list IP66 enclosures. Pair the selected housing with an appropriate dry location and review actual rain, condensation and coastal exposure.

Can rain, spray, condensation or standing water reach the equipment?

- Is the proposed room coastal, and has corrosion exposure been reviewed for the actual model?

03

### Warm enclosed utility area

A dedicated utility area keeps backup equipment separate from everyday living space and leaves access for servicing. Match the format to the room and the loads you want to support.

EU 230 V combines the battery and inverter in one IP21 cabinet. Battery-only options let you work with a compatible external inverter. Preserve cooling and service space; request the exact HP Ultra configuration temperature limits when comparing modular storage.

What is the highest expected room temperature during use?

- Is the inverter/battery combination confirmed, and can cooling and service access remain unobstructed?

Specifications

- Separate charging and discharging limits. TR Pro and HP K list charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. These are not automatic below-zero charging permissions or full-power derating curves.

- Specify the enclosure for the actual room. TR Pro and HP Ultra list IP66; EU lists IP21; TB rack lists IP20; TR standard and HP K list IP20 with IP54 optional. Coastal, wet or dusty exposure still requires model-specific review.

- Size backup around the duration and essential circuits you choose, without assuming an outage schedule. Winter space heating and electric water heating can dominate energy demand and need their own running-power, duration and inverter-capacity review.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

[![Original front terminal and control strip](https://za.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://za.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)

Original front terminal and control strip  Front terminal and control strip, with the negative terminal left and positive terminal right.

[![Negative power terminal, front left](https://za.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://za.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)

Negative power terminal, front left  Negative terminal and minus mark at the front left.

[![Positive power terminal, front right](https://za.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://za.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)

Positive power terminal, front right  Positive terminal and plus mark at the front right.

[![Original communication and control area](https://za.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://za.elvorka.com/assets/product-details/tb-rack-communication-controls.png)

Original communication and control area  Communication connectors, indicators and power switch on the front control strip.

[![Original cell and BMS construction detail](https://za.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://za.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)

Original cell and BMS construction detail  Partial internal illustration showing battery cells and the BMS board.

### Know your interfaces.

#### Power connections

Positive power terminal  Power port on the viewer's right in the illustrated front panel, with the original plus mark.

Negative power terminal  Power port on the viewer's left in the illustrated front panel, with the original minus mark.

#### Communication

Dry Connect (source label)  Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.

COM0 / COM1 parallel ports  Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.

CAN / RS485  Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.

RS232  Communication port named RS232; exact pinout and adapter requirements are not provided.

#### Controls & indicators

Power switch  Power on/off switch as described in the original caption. Operating sequence is not supplied.

SOC / ALM / RUN indicators  Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.

Address identification control  Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

#### Structure & mounting

Laser welding  The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.

Steel holder  Internal steel holder identified as fixing the cells; not an external connector.

Plastic steel belt (source wording)  Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.

Built-in smart BMS  Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.

Portable handle  Steel handle as described in the source. It is not an electrical port.

Source: Residential ESS brochure · PDF page 7 · printed pages 13-14

---

https://za.elvorka.com/en/products/tb-rack/

ELVORKA · eric@elvorka.com